ISSN : 2146-3123
E-ISSN : 2146-3131

Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu
Mustafa Edis 1, Turan Ege 2, Enver Duran 2
1Trakya Üniversitesi Tıp Fakültesi Kalp Damar Cerrahisi Anabilim Dalı, Edirne
2Trakya Üniversitesi Tıp Fakültesi, Kalp Damar Cerrahisi Anabilim Dalı, Edirne
Pages : 102-105

Abstract

A 32-year-old male patient who was followed-up with a diagnosis of amyotrophic lateral sclerosis was inserted a catheter into the left arm via cephalic vein cut-down in order to maintain parenteral nutrition and medical treatment. After the treatment, while the catheter was being removed, it was broken and a large part of it remained in the vessel. The catheter was located on a posteroanterior chest radiograph and removed by venotomy of the subclavian vein.

Keywords : Kateterizasyon/yöntem/yan etki; subklaviyan ven/cerrahi; venöz cut-down/yöntem/yan etki

Viewed : 3475
Downloaded : 926